CJPTM - 44803, PCB KIT-HIGH ISOOCTANE 6 X 1 ML, AROCLOR 1262
- MSDS: CJPTM
- Manufacturer: SUPELCO INC
- Product Name: 44803, PCB KIT-HIGH ISOOCTANE 6 X 1 ML, AROCLOR 1262
- National Stock Number: 6810-00N091842
Product Identification
Product ID:44803, PCB KIT-HIGH ISOOCTANE 6 X 1 ML, AROCLOR 1262
MSDS Date:09/29/1997
FSC:6810
NIIN:00N091842
Status Code:A
MSDS Number: CJPTM
Responsible Party
BELLEFONTE, PA 16823-0048
US
Emergency Phone: 814-359-3441
Info Phone: 814-359-3441
Cage: 54968
Contractor
Telephone: 314-771-5765/414-273-3850X5996
Cage: 54968
Ingredients
(ORAL,RAT) 11,200 MG/KG.
CAS: 37324-23-5
RTECS: TQ1364000
OSHA PEL 0.5 MG/M3
ACGIH TLV: 0.5 MG/M3
PENTANE, 2,2,4-TRIMETHYL-; (ISO-OCTANE)
CAS: 540-84-1
RTECS: SA3320000
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
Hazards
LD50 LC50 Mixture:SEE INGREDIENTS.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:CARCINOGENICITY - HUMAN SUSPECT.
Explanation of Carcinogenicity:AROCLOR 1262 IS CLASSIFIED BY IARC AS A
CLASS 2A CARCINOGEN AND BY NTP AS A GROUP B CARCINOGEN.
POLYCHLORINATED BIPHENYLS (PCB): IARC GROUP 2A, SUP 7. P 323, 1987;
ANTICIPATED CARCINOGEN, NTP 8TH ANN RPT, 1998; LIVER.
First Aid
First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. SKIN: FLUSH
WITH LARGE VOLUMES OF WATER. INHALATION: IMMEDIATELY MOVE TO FRESH
AIR. GIVE OXYGEN IF BREATHING IS LABORED. IF BREATHING STOPS, GIVE
ARTIFI CIAL RESPIRATION. INGESTION: NEVER GIVE ANYTHING BY MOUTH TO
AN UNCONSCIOUS PERSON. NEVER TRY TO MAKE AN UNCONSCIOUS PERSON
VOMIT. DO NOT INDUCE VOMITING.
Fire Fighting
Flash Point Method:CC
Flash Point:=-12.2C, 10.F
Lower Limits:1.1%
Extinguishing Media:CO*2, FOAM AND DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH APPROVED SELF CONTAINED BREATHING
APPARATUS WHEN FIGHTING A CHEMICAL FIRE.
Unusual Fire/Explosion Hazard:CAN REACT VIGOROUSLY WITH REDUCING
MATERIALS.
Accidental Release
Spill Release Procedures:TAKE UP WITH ABSORBENT MATERIAL. VENTILATE
AREA.
Handling
Handling and Storage Precautions:STORE IN SEALED CONTAINER IN COOL, DRY
LOCATION. KEEP AWAY FROM HEAT. STORE IN DRY, WELL VENTILATED AREA.
KEEP AWAY FROM IGNITION SOURCES.
Other Precautions:AVOID EYE OR SKIN CONTACT. AVOID BREATHING VAPORS.
Exposure Controls
Respiratory Protection:WEAR NIOSH APPROVED FACE MASK WITH ORGANIC VAPOR
CANISTER.
Ventilation:USE ONLY IN WELL VENTILATED AREA.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:EYE WASH & DELUGE SHOWER MEETING ANSI DESIGN
CRITERIA .
Supplemental Safety and Health
Chemical Properties
Boiling Pt:=99.C, 210.2F
Melt/Freeze Pt:=-116.C, -176.8F
Vapor Pres:41 MM
Vapor Density:3.90 AIR=1
Spec Gravity:0.690 G/ML (WATER = 1)
Evaporation Rate & Reference:>1 (ETHER = 1)
Appearance and Odor:CLEAR COLORLESS LIQUID.
Stability
Stability Indicator/Materials to Avoid:YES
REDUCING AGENTS.
Disposal
Waste Disposal Methods:COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND
LOCAL REGULATIONS.
Regulatory
SARA Title III Information:AROCLOR 1262 IS SUBJECT TO THE REPORTING
REQUIREMENTS OF SARA TITLE III, SECTION 313.
Federal Regulatory Information:THIS MATERIAL IS NOT LISTED ON THE TSCA
(TOXIC SUBSTANCES CONTROL ACT) INVENTORY. THIS MATERIAL IS INTENDED
FOR R&D USE ONLY & MAY NOT BE USED FOR DRUG, HOUSEHOLD OR OTHER
PURPOSES. IT IS SUBJECT TO T SCA REGULATIONS AT CFR 40 PART 720.36
WHICH DEAL WITH EXEMPTION OF CHEMICALS USED IN RESEARCH &
DEVELOPMENT FROM PMN (PREMANUFACTURE NOTIFICATION) REQUIREMENTS. IN
ADDITION, THE BURDEN OF SAFE USE OF MATERIAL RESTS WITH YOU &,
THEREFORE, IT SHOULD BE HANDLED ONLY BY QUALIFIED PERSONS TRAINED
IN LABO RATORY PROCEDURES & GOOD SAFETY PRACTICES.
State Regulatory Information:CONTAINS MATERIAL(S) KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE CANCER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.